High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 115A, standard version, 100…250V wide band AC/DC coil

High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 115A, standard version, 100…250V wide band AC/DC coil

0 reviews 0 sold. Only 1 remain
0.00ريال
Product Code: LC1G115KUEN
Availability: In Stock
Viewed 2782 times

Product Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 115A 75kW@440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 108mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.

Item specifics

  • Main

  • Contactor application Power switching Motor control
  • Device short name LC1G
  • Poles description 3P
  • Range TeSys
  • Utilisation category AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5
  • [Ie] rated operational current 250 A (at <40 °C) at <= 1000 V AC-1 115 A (at <60 °C) at <= 440 V AC-3
  • [Uc] control circuit voltage 100...250 V AC 50/60 Hz 100...250 V DC
  • [Ue] rated operational voltage <= 1000 V AC 50/60 Hz <= 460 V DC
  • Range of product TeSys Giga
  • Product or component type Contactor
  • Complementary

  • Associated fuse rating 125 A aM at <= 440 V for motor 125 A aM at <= 690 V for motor 315 A gG at <= 690 V
  • Auxiliary contact composition 1 NO + 1 NC
  • Average impedance 0.00018 Ohm
  • Coil technology Built-in bidirectional peak limiting
  • Compatibility code LC1G
  • Connection pitch 35 mm
  • Connections - terminals Power circuit: bar 2 - busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 185 mm² Power circuit: bolted connection Control circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable end Control circuit: push-in 2 0.5…1.0 mm² with cable end Control circuit: push-in 0.75…2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 0.75…2.5 mm² - cable stiffness: flexible with cable end
  • Control circuit voltage limits Operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C) Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)
  • Depth 193 mm
  • Height 193 mm
  • hold-in power consumption in VA (50/60 Hz, AC) 12.4 VA
  • hold-in power consumption in W (DC) 7.8 W
  • inrush power in VA (50/60 Hz, AC) 540 VA
  • inrush power in W (DC) 380 W
  • Irms rated making capacity 1560 A at 440 V
  • Maximum operating rate 600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4
  • Mechanical durability 8 Mcycles
  • Motor power hp 30 hp at 200/208 V 60 Hz 40 hp at 230/240 V 60 Hz 75 hp at 460/480 V 60 Hz 100 hp at 575/600 V 60 Hz
  • Motor power kW 30 kW at 230 V AC 50/60 Hz (AC-3e) 55 kW at 400 V AC 50/60 Hz (AC-3e) 55 kW at 415 V AC 50/60 Hz (AC-3e) 75 kW at 440 V AC 50/60 Hz (AC-3e) 75 kW at 500 V AC 50/60 Hz (AC-3e) 75 kW at 690 V AC 50/60 Hz (AC-3e) 30 kW at 230 V AC 50/60 Hz (AC-3) 55 kW at 400 V AC 50/60 Hz (AC-3) 55 kW at 415 V AC 50/60 Hz (AC-3) 75 kW at 440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 75 kW at 690 V AC 50/60 Hz (AC-3) 30 kW at 230 V AC 50/60 Hz (AC-4) 55 kW at 400 V AC 50/60 Hz (AC-4) 55 kW at 415 V AC 50/60 Hz (AC-4) 65 kW at 440 V AC 50/60 Hz (AC-4) 65 kW at 500 V AC 50/60 Hz (AC-4) 75 kW at 690 V AC 50/60 Hz (AC-4)
  • Mounting support Plate
  • Net weight 3.6 kg
  • Operating time 40...70 ms closing 15...50 ms opening
  • Overvoltage category III
  • Pole contact composition 3 NO
  • Power dissipation per pole 10 W AC-1 - Ith 250 A 3 W AC-3 - Ith 115 A
  • Product Certifications CB Scheme CCC cULus EAC CE UKCA EU-RO-MR by DNV-GL
  • Rated breaking capacity 1040 A at 440 V
  • Safety reliability level B10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
  • Standards EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ
  • Tightening torque 18 N.m
  • Width 108 mm
  • [Icw] rated short-time withstand current 1.1 kA - 10 s 0.64 kA - 30 s 0.52 kA - 1 min 0.4 kA - 3 min 0.32 kA - 10 min
  • [Ith] conventional free air thermal current 250 A (at 40 °C)
  • [Uimp] rated impulse withstand voltage 8 kV
  • [Ui] rated insulation voltage 1000 V
  • Environment

  • Ambient air temperature for operation -25…60 °C
  • Ambient air temperature for storage -60…80 °C
  • Colour Dark grey
  • IP degree of protection IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
  • Mechanical robustness Vibrations 5…300 Hz 2 gn contactor open Vibrations 5…300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed
  • Permissible ambient air temperature around the device -40…70 °C at Uc
  • protective treatment TH
  • Packing Units

  • Number of Units in Package 1 1
  • Number of Units in Package 2 12
  • Package 1 Height 25.500 cm
  • Package 1 Length 32.000 cm
  • Package 1 Weight 4.512 kg
  • Package 1 Width 18.500 cm
  • Package 2 Height 75.000 cm
  • Package 2 Length 80.000 cm
  • Package 2 Weight 66.008 kg
  • Package 2 Width 60.000 cm
  • Unit Type of Package 1 PCE
  • Unit Type of Package 2 S06

Write a review